<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15204</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: remove plate from conveyor or check sensor
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_3244</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Check conveyer plate sensor and cables.
For S conveyer check fence.
Check rollers operate.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Lift lid of plate rotator and remove plate or push into processor, then Resume.
</text></DescriptionText>
</OperatorAction>
<Cause>
This error is reported if there is still a plate sensed in the conveyer when
shutting down the rollers after timing out:
processor_infeed_delay (if processor interface enabled) + plate_process
(error only reported if plate conveyer is enabled.)
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/al_cal_npc.xml</LinkAddress><LinkTitle>NVS: al npc</LinkTitle></Link>
<Link><LinkAddress>../nvs/altim_cfg_plate.xml</LinkAddress><LinkTitle>NVS: altim plate</LinkTitle></Link>
<Link><LinkAddress>../nvs/aldly_cal_pid.xml</LinkAddress><LinkTitle>NVS: aldly pid</LinkTitle></Link>
<Link><LinkAddress>../commands/conveyer.xml</LinkAddress><LinkTitle>Command: conveyer</LinkTitle></Link>
<Link><LinkAddress>../commands/processor.xml</LinkAddress><LinkTitle>Command: processor</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:56 2008 PST
</Updated>
<Links>
</Links>
</Error>